FLOATING LEVEL SWITCH

The SK-12A float level switch is a ball-type
mechanical switch, encased in a PVC housing
that seals the switch mechanism in an air filled
watertight chamber. Due to the enclosed air
section, the SK-12A will attempt to float in liquid
with an SG ≥ 1. The float level is used for level
detection and dry run protection in bulk water
reservoirs.

PRESSURE BOOSTER SYSTEM
COMPONENTS

This pressure boost system comprises of: – 5-way connector (brass) – Pressure gauge – Pressure switch (see next page) – Non-return valve (1” brass) – Flexible hose (1”x1”x0.8m) – Flexible hose (1”x1”x0.4m) – Suction Hose Kit 25mm x 300mm

PRESSURE SWITCH: SK-2

The SK-2 is a mechanical type of pressure switch used to control electric driven domestic type pumps. When the internal pressure of the pipe is more than the setting pressure, the pressure control will disconnect the load power supply to the pump and connect the power again when pressure drops below the set pressure. The SK-2 has two operating points; one on the rising pressure trip point and the other on the falling pressure (reset point). The differential is the difference in pressure between the trip point (cut-out) and the reset point (cut-in).

PRESSURE TANKS:
BLADDER TYPE

The bladder type series of pressure tanks is designed to provide reliable storage for pressurized water in a booster pump system. The pressure tank effectively releases its stored volume of pressurised water on demand and prevents pump startups for demands lower than its storage capacity. The internal bladder ensures that there is no contact between the water and the air

FLOW CONTROL SWITCH: SKD-2

Flow from 0 to 6m3/h. The SKD-2 flow control starts the pump automatically when pressure decreases (for example taps are opened) and stops it when there is no flow/water shortage (for example taps are closed). It can be used for drinking water or nonportable water piping systems.

FLOW CONTROL SWITCH: SKD-2

Flow from 0 to 6m3/h. The SKD-2 flow control starts the pump automatically when pressure decreases (for example taps are opened) and stops it when there is no flow/water shortage (for example taps are closed). It can be used for drinking water or nonportable water piping systems.

FLOW CONTROL SWITCH:
PS06-1C

PERFORMANCE RANGE
Direct Flow: 0 to 6m3/hour
The PS06-1C is a combination of a flow controller and a pressure sensor. It can be used
in flow / pressure control system for non-particle laden liquids of non-chemically aggressive
nature